MRCOOL 24K BTU Downflow Two-Stage Heat Pump - Left Return,  - GCHPD024TGTANXL

MRCOOL 24K BTU Downflow Two-Stage Heat Pump - Left Return, - GCHPD024TGTANXL

$4,324.99
Sale price  $4,324.99 Regular price  $5,766.00
Skip to product information
MRCOOL 24K BTU Downflow Two-Stage Heat Pump - Left Return,  - GCHPD024TGTANXL
👑 Offre exclusive : -15% uniquement cette semaine avec le code PRIVILEGE
(offre valable jusqu'à dimanche 23h59)

MRCOOL 24K BTU Downflow Two-Stage Heat Pump - Left Return, - GCHPD024TGTANXL

$4,324.99
Sale price  $4,324.99 Regular price  $5,766.00
In stock
lokicam shipping

Expédition sous 72h

loki garantie

Garantie 90 jours

4,7/5 sur 4300+ avis

⚡ Commandez avant 00h 00m 00s .
Payment methods
    Livraison et retours
    • Traitement et expédition : 1 à 3 jours après validation de votre commande
    • Livraison en France métropolitaine : 6 à 9 jours. Lien vers la politique
    • Retours : vous disposez de 30 jours après réception pour nous retourner vos articles. Lien vers la politique

    MRCOOL 24K BTU Downflow Two-Stage Heat Pump - Left Return,  - GCHPD024TGTANXL

    24K BTU Downflow Two-Stage 230V 1-Phase 60Hz CuNi Coil Left Return

    Features
    • Qualifies for federal tax credit, and other incentives
    • Highest energy efficiency in its class
    • Safety high and low pressure switches
    • Quiet operation
    • Full featured sinusoidal eon motor control technology
    • Insulated sloped stainless steel drain pan
    • Advanced unit control board with diagnostic LEDs
    • Double O-ring water connections
    • Easy service access
    • Optional domestic water pre-heating
    • Made in the USA
      Specifications
      Product Dimensions
      25.75"W x 32"D x
      56"H
      Product Weight 325 lbs
      EER Ground Water (FULL) 27.40 / Ground Loop (FULL) 17.95
      EER Part Load Ground Water (PART) 36.50 / Ground Loop (PART) 25.93
      COP 47 Ground Water (FULL) 5.40 / Ground Loop 4.20 (FULL)
      COP 47
      Part Load
      Ground Water (PART) 5.50 / Ground Loop 4.70 (PART)
      HSPF Ground Water Fluid Flow Rate | COOLING: (PART) 7 - 8 (FULL) / HEATING: (PART) 7 - 8 (FULL)
      AFUE Ground Loop Fluid Flow Rate | COOLING: (PART) 7 - 8 (FULL) / HEATING: (PART) 7 - 8 (FULL)
      CFM COOLING (PART) 850 - 1000 (FULL) / HEATING (PART) 800 - 950 (FULL)
      Tonnage 2
      Cooling Capacity Ground Water (PART) 23000 - 29000 (FULL) / Ground Loop (PART) 21900 - 27000 (FULL)
      Heating Capacity Ground Water (PART) 19000 - 25700 (FULL) / Ground Loop (PART) 16500 - 18500 (FULL)
      Voltage 230V/
      60Hz/34A
      Phase 1
      Cycle 60
      Stage Two-Stage
      Max Fuse Breaker 34.0 (W/O Desupe
      Min Circuit Ampacity 21.9
      Configuration Left Return Downflow
      Color Gray
      Max Coverage Area 1000
      Refrigerant Type R-410A
      Compressor Motor Type Scroll
      Blower Motor Type Axial Flux (No Shaft) BLA
      Blower Motor HP 3/4
      Filter Type Replaceable
      Contains Electronics
      Chemicals
      Aerosol
      Compressed Gas
      Proposition 65 Warning Yes
      What our Experts Think
      • Two‑stage efficiency & comfort: Two‑stage operation delivers smoother temperature control and improved dehumidification compared to single-stage systems.

      • Optimal sizing: 24,000 BTU (2‑ton) capacity is ideal for homes or spaces up to ~1,000 sq ft with balanced heating and cooling.

      • Downflow, left‑return design: Perfect for installations requiring vertical airflow with ductwork entering from the left.

      • Reliable performance: Scroll compressor and quality blower motor ensure quiet, consistent operation with easy service access.

      • Maintenance‑friendly: Replaceable filters simplify upkeep and help maintain indoor air quality.


      Q&A

      Q: What is the MRCOOL GCHPD024TGTANXL?
      A: A 24,000 BTU (2 ton) downflow, two-stage heat pump designed for efficient, year-round heating and cooling in ducted HVAC systems.

      Q: What configuration does it use?
      A: Downflow orientation with a left return, ideal for vertical HVAC installations.

      Q: How does it perform?
      A: Features a two-stage scroll compressor and axial flux blower for quiet, efficient operation in medium-sized homes.

      Q: What refrigerant and power does it require?
      A: Uses R‑410A refrigerant and operates on 230 V single-phase power.

      Q: Is it energy efficient?
      A: Yes, designed to meet ENERGY STAR® standards for energy savings.


      Maintenance Tips
      • Replace or clean air filters every 1–3 months

      • Keep outdoor condenser unit clear of debris, leaves, and dirt

      • Inspect refrigerant lines and connections for leaks or damage

      • Ensure condensate drain lines are unobstructed

      • Check thermostat settings and batteries regularly

      • Schedule annual professional inspection for coils, refrigerant, and electrical components

      Vous avez une autre question ?

      Consultez notre FAQ complète pour plus de réponses sur la livraison, l’installation ou le fonctionnement des produits.

      Besoin d’aide immédiate ? Écrivez-nous à boutique@lokicam.com ou via le chat instantané, notre équipe vous répond sous 12h.

      boutique lokicam

      À propos de LokiCam

      Une marque française née d’un besoin simple : voir sans être vu.

      Inspirés par Loki, symbole de stratégie et de ruse dans la mythologie nordique, nous avons fondé LokiCam pour ceux qui veulent tout voir sans jamais être vus.

      Ici, la discrétion est une arme, la technologie un levier, et la sécurité une priorité. Nos dispositifs sont conçus pour celles et ceux qui refusent de laisser leur vie privée au hasard.

      Rejoignez la communauté LokiCam et prenez le contrôle. Observation, anticipation, action – sans compromis.

      À propos

      Vous aimerez aussi

      4,7/5 sur 4300+ avis

      lokicam shipping

      Expédition 72h + Protection 90 jours

      lokicam france

      Support client français